ROCHEM FILTER CLEANER is a heavy duty liquid compound specially designed to remove carbonaceous residue formed by oil and other petroleum products. It has extremely high solvency and penetrating powers, yet remains economical and safe for normal usage. Rochem Filter Cleaner is neither acidic nor basic, has a high flash point and is non-corrosive to metals. It can be used either with or without heat.
SPECIFICATION
Colour - Muddy Brown
Consistency - Liquid
Sp. gravity - 1.0 to
1.10
pH - Neutral
Viscosity - 40 Sec at
40°C by Red wood
Viscometer No.1
APPLICATION
ROCHEM FILTER CLEANER is delivered ready for use. It is particularly effective for cleaning of Metal/Ceramic Oil filters and permanently fixed Oil Coolers or Heaters. These units are regularly contaminated by suspended particles in partially carbonized oils. Timely cleaning prevents the formation of hard coke like adherents which are difficult to remove at a later stage.ROCHEM FILTER CLEANER is equally efficient for in-place cleaning (CIRCULATION METHOD) and for soaking of individual parts (DIP TANK METHOD). It may be desirable to heat ROCHEM FILTER CLEANER if you encounter heavy carbon deposits or if rapid cleaning is necessary. Heating to 49°C (120°F) will quadruple the solvency power. However, it is recommended that the temperature does not exceed 60°C (140°F). Nor should heat be used in an enclosed or unventilated area.
INSTRUCTIONS FOR USE
Dip Tank Method:
Simply immerse the parts
to be cleaned into a
suitable container
filled with ROCHEM
FILTER CLEANER. Hang the
objects in a wire basket
or from a wire so they
are off the bottom and
completely immersed in
the solvent. It is
desirable to stir or
agitate the solvent when
the deposits are
exceptionally heavy.
When clean, rinse the
parts with water and
then dry by wiping or
with compressed air.
Stubborn deposits can be
brushed away with a
stiff bristle brush once
they have been softened
by ROCHEM FILTER
CLEANER. To reduce
soaking time use heat as
described above.
Circulation method:
Remove excess oil
remaining in the fuel
oil heater to be cleaned
by blowing air or steam
through the oil side.
Connect the
recirculation system
which requires a
circulation pump, carbon
remover reservoir and
temporary hoses or
pipes. (Connect hose
from the reservoir to
the suction side of
pump, connect hose from
the pump discharge to
fuel oil heater, and
connect hose from
opposite end of fuel oil
heater back to
reservoir). Circulate
ROCHEM FILTER CLEANER
from 4 to 24 hours,
depending on the type of
deposits to be removed
as well as temperature
of the circulating
solvent. When completed,
drain the solvent to the
reservoir, then flush
the unit with flushing
oil, steam or water. If
steam is required, admit
steam to the steam side
of the heater. After
extensive use, ROCHEM
FILTER CLEANER is likely
to get contaminated with
sludge and deposits. At
this time pour off the
liquid, clean the
deposits from the tank,
then return the liquid
adding fresh ROCHEM
FILTER CLEANER to make
up for the used up
quantity.
HANDLING INSTRUCTIONS
When using ROCHEM FILTER CLEANER, ensure adequate ventilation and keep away from extreme heat or open flame. Avoid breathing vapors. Do not let eyes, skin, or clothing come in direct contact with the liquid. If swallowed seek medical attention. Store in a cool, dry and well ventilated place.